* This module only updates some information on the screen when a new
display is added/removed, hence it makes sense to update it only when
the i3-bar is refreshed.
Add a new parameter engine.workspacewrap (default to true) that, if set
to false, makes the workspace change via mouse wheel stop when hitting
the first/last workspace of an output (identical to how i3wm bar itself
behaves).
fixes#188
Add a parameter that allows the user to enable/disable workspace
scrolling via the status bar.
By default, scrolling is enabled, to disable it, add the following
parameter to your bumblebee-status invokation:
-p <other parameters> engine.workspacewheel=false
see #188
After listening to an audio stream for longer than 10 minutes "mpc -f "tag artist %artist%\ntag title %title%"" will start producing lines with slightly different separation, which caused the bar to fail.
In a theme file, it is now possible to provide an array of "color
definitions", which allow you to use names instead of colors throughout
the theme file.
Currently, only the colorset "wal" is supported, which reads all colors
from the wal JSON file (~/.cache/wal/colors.json) and makes them usable
in the theme (as "foreground", "background", "cursor", "color12", etc.).
An example of this can be found in the theme wal-powerline.
see #185
This file has no actionable code when executed directly from a shell. It contains only a `class` as it is a bumblebee module.
so the shebang should be removed.
On intel pstate drivers only the normal frequency is written to /proc/cpuinfo, not accounting for scaling/turbo.
This should fix that, though it needs testing on other computers (AMD, intel without pstate) because I am not
certain that the file only exists on Intel pstate.
In order to do that, change the theme engine so that a theme can
override settings in the iconsets. Was probably a bug to begin with that
this was not possible.
In python2, filter returned a list, but in python3 it returns an iterator. So
we wrap this in a list() so that it works in both. We also want to count the
unread notifications, so this should be reflected in the code.
Override sys.stdout and sys.stderr in an attempt to enforce utf-8
encoding. Probably this will cause all kinds of weird issues down the
line, but at least, it seems to solve the immediate issue.
fixes#176
Replace textwrap.shorten() with custom implementation, since it is only
available since Python 3.4. While at it, catch i3 exceptions in order to
make unit tests (hopefully) run through.
Also, Updated README.md
see #174
The "base" currency can now be configured using the parameter "source",
and the "symbols" to be resolved can be configured using the parameter
"destination", which is a comma-separated list.
see #169
If a callback command cannot be executed, do not terminate the whole
bar. Furthermore, if such a failure occurs, try to fall back to a
globally (i.e. non widget-specific) command, so that callbacks
registered in the engine itself (such as mouse-wheel scrolling) still
function properly.
fixes#166
* A module can override the method "hidden" to specify when all it's
widgets should be hidden.
* Implement hidden for cmus and spotify
* Fix problem that cmus widgets were not displayed correctly
fixes#157
was having some problems with the current implementation as i have multiple values with the same name in sensors -u.
this way it is unambiguous and *should* just work everywhere with no lm_sensors required, though some distros might move the pseudo file elsewhere, not sure, but thats why it is configurable.
testing would be great.
also, the file is simpler too.
If a configuration parameter is *not* specified with -p on the
commandline, look for a INI style configuration file as fallback in
~/.bumblebee-status.conf or ~/.config/bumblebee-status.conf.
Section must be "module-parameters", like this:
[module-parameters]
github.token=<your github token>
fixes#138
The module now creates a widget for each battery device it detects and
shows the status for each of them (I don't know of anyone with more than
a single battery, but if I'm overhauling the module anyhow, might as
well do it comprehensively).
fixes#117
If the current volume and mute status cannot be retrieved, the most
likely explanation is that the pulseaudio daemon is not running.
Automatically start it in such a case.
Also, add a parameter "autostart" to the pulseaudio module to disable
this behaviour in case it causes issues.
see #108
This Module Displays the Status, Song, Artist and Time of the current song played or paused in mocp.
Clicking the Modules toggles play/pause.
I'm no programmer so alteration and feedback is welcome.
Best regards, Chrugi
If data cannot be retrieved for some reason (be pretty generous about
that by catching generic exceptions), instead of terminating the whole
status bar, simply report unknown data.
see #110
Since the module requires the pulseaudio daemon to be running, in order
to query system information such as the default source/sink and the
current volume, start the daemon, if necessary.
fixes#108
A previous commit broke the traffic module by deleting widgets during
each iteration. This is fatal as the widgets contain the traffic
information from the previous iteration, for delta calculation.
Store previous traffic data in the module itself instead.
In order to (hopefully) achieve localization independence, switch from
using pactl for retrieving pulseaudio information to pacmd, which seems
to be unaffected by the LANG environment variable.
fixes#103
To avoid "stray" devices being kept in the list, empty the widgets list
during each iteration and re-populate it from the list of available
interfaces.
fixes#101
The optional parameter "states" can now be used to filter which
interfaces to display. "^" can be used for negation.
For example, to only show "up" interfaces:
-p traffic.states=up
To show all interfaces not in "down" state:
-p traffic.states=^down
fixes#98
psutil.cpu_percent() only outputs to one decimal place anyway, so the trailing 0 is useless.
The prepended 0 is also not important, will only be not 0 at 100% utilization, so why not let it be 100% then and take up one less column otherwise?
No change to default behaviour, but adds boolean to only display used rather than used, total and percentage.
To only show used memory:
-p memory.usedonly=1
OK - I admit it: Mostly for the benefit of Travis and automated testing,
which complains about the DBusException, move to a more generic
exception.
However, this is probably a good idea anyhow, because independently of
the error, setting the song to an empty string is probably the best bet.
Allow the user to filter the state of devices that should be displayed.
It's possible to use both white- and blacklists (and combinations).
For example, to only show devices in state "up":
-p nic.states=up
To only show devices that are not down:
-p nic.states=^down
fixes#84
For modules that use aliases, until now, *only* the alias theme was
considered. This is typically a bad idea (tm), as the "generic" case is
that of a module theme (e.g. "disk", not that of a theme per instance of
the module (i.e. "home", "root", etc.)).
Therefore, introduce the concept of a "class" theme that can be
optionall overridden by a specific module theme.
As a pleasant side-effect, this should bring back the disk icons for all
instances of the disk module :)
fixes#79
If a module defines a callback for a widget's text, an optional
decorator "@bumblebee.output.scrollable" can be used to make the text
scrollable.
In those cases, the desired width is set to (in decreasing order of
priority):
1. whatever the widget defines as "theme.width"
2. whatever the theme defines as "width" for the module
3. whatever the commandline parameter "width" for the module is set to
4. 30 (determined by unfair dice roll)
see #27
Added theme-options ("minwidth" and "align") for setting the minimum
width and the alignment of a widget.
Also, allow widget to provide defaults for the theme options by setting
an attribute in their store called "theme-<name of the theme option>".
For example, a widget can now define a default alignment by using:
widget.set("theme-align", "default-value").
Set the minimum width for uplink and downlink widgets to "down 1000MB",
which should be plenty, and change alignment to right (personally, I
find this looks nicer).
To not have the icons on the left side "jump around" depending on the
value, make them suffixes.
If this solution is not sufficient, alternatively, the widget itself
could perform value padding. In that case, the whole alignment and
min-width settings would be obsolete and the icons could remain on the
left side.
Added theme-options ("minwidth" and "align") for setting the minimum
width and the alignment of a widget.
Also, allow widget to provide defaults for the theme options by setting
an attribute in their store called "theme-<name of the theme option>".
For example, a widget can now define a default alignment by using:
widget.set("theme-align", "default-value").
* use psutil instead of "ifconfig" in order to avoid external command
calls
* fix a small bug in the ascii theme (missing colon)
* show statistics per-nic
* If an exception is thrown, catch it and show a (somewhat) nice error
message in the i3bar instead of the normal content
* Add a flag "-d" for debugging into a debug log. Currently, this only
logs commandline calls as they occur and their return values, as well
as exceptions.
fixes#58
Until now, manually specifying an interval did not work, as a cast to
float was missing. Now, it's possible to specify an update interval in
seconds via "-p interval=<interval>"
fixes#54
Seems like subprocess and friends (Popen, communicate) are not so easy
to mock cleanly. Therefore, start from scratch and carefully write test
by test, until (at least) the old test coverage has been restored.
Instead of executing an external call to "uname", use the standard
Python module "platform" to retrieve information about the kernel used.
Positive side-effect: This is portable, if i3 ever exists on Windows :P
Since requests works the same for python2.7 and python3.x, use requests
instead of urllib (which returns a string in python2.7, but byte data in
python3.0, at least).
* Use app-specific API key for bumblebee-status
* Add some parameters (location, unit, update interval)
* Make interval calculation based on time, not number of calls
Somehow, the fix in the previous commit didn't work, it seems that
sometimes epoll() doesn't trigger, even if there is more data in
sys.stdin. I'm sure I'm doing something horribly wrong here.
Anyhow, as a quick fix, check for the open bracket to be sure to not
buffer the first event too long.
Re-enable the possibility to define custom mouse actions by binding
commands to "<alias|module>.<left-click|right-click|...>". These
commands are then executed as shell commands.
fixes#30
Instead of having a thread that runs in the background continuously,
spawn a new one for every update interval. That speeds up the tests
quite a lot.
see #23
Show RTT measured by ICMP echo request/replies for a given host.
For that to work correctly, change the "full_text" callback for a widget
so that the widget itself is also passed as argument in the callback
method. That actually makes a lot of sense, since the widget can now be
used as a repository of state information.
see #23
Quite a lot of modules use the "if higher X -> critical, if higher Y ->
warning" idiom now, so extracted that into a common function for reuse.
see #23
Until now, as soon as a widget registered *any* callback, the default
callbacks (e.g. scroll up/down to go to next/previous workspace) didn't
work anymore, as there was a better match for the general registration
(even though not for the button).
To fix this, merge the callback registration into a flat registration,
where a key is calculated from the ID of the registrar and the
registered button.
see #23
If the computer runs on AC, display that instead of showing "100%" in
the status.
Also, if reading the charging status fails for some reason (except the
computer being on AC), go into critical state and display "n/a".
see #23
Allow modules to define aliases. This replaces the symlink mechanism
that was in place previously, because it was a bit ugly (and confused
code climate).
see #23
Make input thread non-blocking by using select(). This increases the CPU
utilization a bit (depending on the timeout), but makes the thread exit
cleanly, even if an exception is thrown in the main thread.
see #23
If a widget exists for an interface that is not there anymore (i.e. a
tunnel interface that has been removed, or a USB device that has been
unplugged), remove that widget from the list.
see #23
Re-add the NIC module with all its functionality (hopefully...).
This introduces a new concept: Instead of having separate queries for
critical and warning (which really are just another set of states), a
module can now return a list of states for each widget. All the state
information is then merged together into a single theme. So, for
instance, the NIC module can return a state saying "critical -
wlan-down", which applies the theme information for both "critical" and
"wlan-down".
see #23
I cannot get the min_width property to work right now, so in order to
fix the width of the CPU widget, pad the utilization to 3 digits (so
that even 100% aligns nicely).
see #23
The cpu module now has cpu.warning and cpu.critical thresholds. If the
CPU utilization is higher than any of those values, the widget's state
changes to warning or critical, respectively.
see #23